High temperature furnace temperature uniformity test method and implementation points

High temperature furnace temperature uniformity test method and implementation pointsomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
1. Test purpose and timingomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The temperature uniformity test of high temperature furnace is to determine the effective working area of the furnace (charging space that meets the process temperature uniformity requirements) to ensure the quality consistency of workpieces after heat treatment2. The test timing is divided into two categories:omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Initial test: Before the new furnace is put into production, after overhaul or process adjustment, the full working temperature range (lowest to highest temperature) needs to be verified.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Periodic test: Regularly carried out according to the furnace level, usually selecting common temperature points to ensure long-term stable operation of the equipment.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. Main test methods and stepsomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2.1 Thermocouple method (core standard method)omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Thermocouple arrangementomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Arrange multiple thermocouples in the center, four corners, different heights and close to/away from the heating element of the furnace to ensure coverage of key areas.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Use a clamp or adhesive to fix the thermocouple to ensure close contact with the surface to be measured and reduce measurement errors.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Temperature measurement and data acquisitionomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Raise the furnace temperature to the set temperature and run it stably, and record the temperature of each point synchronously through a multi-channel thermometer or data acquisition system.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The test conditions need to simulate the actual production status, such as heating rate, atmosphere parameters (atmosphere furnace), circulation fan operation, etc.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Data analysisomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Calculate the maximum temperature difference (difference between the highest point and the lowest point) and deviation (deviation of the temperature at each point from the set temperature).omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Determine whether it is qualified according to the process standard. For example, high-precision heat treatment usually requires a temperature difference of ≤±5℃.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2.2 Temperature sensor array methodomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Array installation: Arrange sensor arrays evenly distributed in the furnace or in key areas, supporting wired/wireless data transmission.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Real-time monitoring: Generate temperature distribution diagrams through software, intuitively display the temperature field distribution in the furnace, and quickly locate hot spots or cold spots.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Advantages: Suitable for large furnaces or complex structure furnaces, with higher data resolution than traditional thermocouple methods.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2.3 Thermal imager assisted detectionomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
External scanning: Scan the outside of the furnace during operation, and indirectly analyze the temperature distribution in the furnace through infrared radiation.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Image analysis: Judge the temperature uniformity based on the color difference of the thermal image (bright high temperature, dark low temperature), and assist in identifying heat leakage in the furnace wall or abnormal heating elements.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Limitations: It only reflects the surface temperature of the furnace body, and other methods need to be combined to verify the actual situation in the furnace.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2.4 Actual workpiece test methodomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Workpiece selection: Use samples with similar materials, shapes and sizes to the production workpieces to simulate the actual loading state.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Monitoring point layout: Paste thermocouples or temperature labels at key positions on the surface of the workpiece to record the temperature changes during the entire heat treatment process.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Result evaluation: Through the temperature difference of different parts of the workpiece, the adaptability of the furnace to actual production is directly verified.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
III. Test system composition and implementation conditionsomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
3.1 Core equipmentomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Temperature sensor: precious metal thermocouple (S type, 0-1600℃) or cheap metal thermocouple, accuracy ±0.5℃omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Data acquisition system: multi-channel synchronous acquisition, sampling frequency ≥1 times/secondomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Temperature measuring frame high temperature resistant material: (such as ceramic) to avoid affecting the airflow in the furnace
muffle furnace
3.2 Test conditionsomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
No-load/loaded test: No-load test is the default, and loaded test is performed when necessary (load capacity ≥ 50% of the rated furnace load).omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Environmental control: Keep the furnace door closed and the atmosphere in the furnace stable (such as vacuum degree, protective gas flow rate).omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
IV. Result evaluation criteriaomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Temperature uniformity index: The maximum deviation of the temperature of each test point relative to the set temperature is the core index, and the specific threshold must meet the process standard (such as aerospace standard AMS2750G).omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Effective working area division: Determine the qualified loading area based on the test data. Exceeding the range may cause fluctuations in the quality of the workpiece.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
V. PrecautionsomtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Thermocouples and data acquisition systems need to be calibrated before testing to ensure measurement accuracy.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Take the average value of multiple tests to reduce the impact of random errors.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Record test environment parameters (such as room temperature and humidity) to facilitate result traceability and abnormal analysis.omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
omtMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The above method can systematically evaluate the temperature uniformity of the high-temperature furnace and provide data support for process optimization and quality control.