Common faults of vacuum furnace and their solutions

Common failures of vacuum furnaces mainly include abnormal temperature, insufficient vacuum, mechanical structure failure, and sudden power outages, water outages and other emergency situations. Depending on the specific type of failure, measures such as parameter calibration, component replacement, seal inspection or emergency cooling must be taken.vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Abnormal temperature failure and handlingvtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Overtemperature alarmvtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
1. Check whether the temperature controller parameters are abnormal, and refer to the normal equipment for calibration. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. Test the resistance of the solid-state relay output terminal, and replace it if it is broken. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
3. Shake the thermocouple probe to observe the display fluctuation, and replace the probe if the contact is poor. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The temperature does not reach the set value.vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
1. Verify whether the thermocouple is damaged, and it can be interchanged with other normal thermostats for testing. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. Check the power-on status and current of the heating tube, and check the circuit or replace the component if it is abnormal. ‌‌
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
 
vacuum furnace
Insufficient vacuum problemvtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
‌1. Basic inspection‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Confirm that the gas source pressure (above -95kPa) and compressed air (0.4-0.6MPa) are normal. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Check the vacuum gauge parameters, furnace door sealing strips and pipeline interface sealing. ‌‌‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
‌2. Deep processing‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
When the pump oil is contaminated or too little, the vacuum pump needs to be cleaned and the oil needs to be changed. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
To check the leak point, turn off the power and check the solenoid valve, pipe joints and other parts. ‌‌
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Mechanical structure failure ‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
‌1. Furnace door problem: Loose hinges and damaged sealing strips need to be repaired or replaced. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
‌2. Fan abnormal noise: Clear foreign matter from the wind wheel or tighten the motor screws. ‌‌vtQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
‌3. Pneumatic valve failure: Check the solenoid valve and air pressure, and the faulty valve body needs to be replaced. ‌‌